Sheets of plywood or OSB for a subfloor, a wall or a gable roof — by area and laid out sheet by sheet, with nails per sheet.
Plywood & OSB sheathing calculator
12 sheets384.00 SF ÷ 32 SF per sheet
- Area to cover
- 384.00 SF
- Sheets (by area)
- 12 sheets
- Laid out sheet by sheet
- 12 sheets (4 × 3)
- Nails per sheet
- 43 nails
- Nails in all
- 516 nails
These sketches are here to help you order material and price the work quickly. They are not engineered or shop drawings — always build from your approved project drawings.
IRC Table R602.3(1): 6" at panel edges, 12" in the field (6" in the field for roofs with 8d common nails since the 2021 IRC). Shear walls and high-wind areas need closer nailing — follow the plans.
Adjust▾
Show the math▾
- Arealength × width24' 0" × 16' 0" = 384.00 SF
- Sheetsarea ÷ sheet SF, rounded up384.00 SF ÷ 32.00 SF = 12
- Laid out sheet by sheet(width ÷ sheet width, rounded up) × (length ÷ sheet length, rounded up)( 16' 0" ÷ 4' 0" ) × ( 24' 0" ÷ 8' 0" ) = 12
- Framing lines under a sheetsheet ÷ framing spacing, rounded up, + 196 ÷ 16 (in), rounded up, + 1 = 7
- Nails per sheet2 edge lines × (width ÷ edge spacing + 1) + middle lines × (width ÷ field spacing + 1)2 × (48 ÷ 6 + 1) + 5 × (48 ÷ 12 + 1) (in) = 43
- Nails in allnails per sheet × sheets43 × 12 = 516
Where the numbers come from
- Sheets: Area ÷ sheet SF (4' × 8' = 32 SF), rounded up. Laid out: whole sheets per row × rows, offcuts not reusedThe area count assumes offcuts get used elsewhere; the layout count is the most you would need for a plain rectangle. Floors and roofs: long side across the joists or rafters, end joints staggered (APA). Walls: sheets stand up, openings sheathed over and cut out. Same area rule as the wall-framing page.Source
- Roof area: Plan area × √(1 + (rise ÷ 12)²) — 6/12: √1.25 = 1.1180Worked out from the right triangle of rise and run: a 12" run at 6" rise is √(12² + 6²) = 13.42" of rafter, 13.42 ÷ 12 = 1.118. Measure the plan width eave to eave including overhangs. The layout assumes a gable roof (two planes); a hip roof has the same area but more cuts.
- Nail spacing: IRC Table R602.3(1): 6" at supported panel edges, 12" at intermediate supports; roof field 6" with 8d common nails since the 2021 IRCThe linked table is the 2012 IRC text (6" edges / 12" field for subfloor, roof and wall sheathing; high-wind footnotes call for tighter roof nailing). The 2021 IRC cut roof field spacing to 6" for 8d common and RSRS-01 nails (12" kept for 10d common or 8d deformed shank) — Simpson Strong-Tie summary: https://seblog.strongtie.com/?p=5097. Floor edges perpendicular to the joists usually aren't blocked (T&G), so only the framing lines get nails. Braced walls, shear walls and high-wind or seismic areas need closer nailing — follow the plans.Source
Saved results
Nothing saved yet. Tap Save to keep a result on this device.